E14燈頭量規(guī)
E14燈頭、燈座量規(guī)符合標(biāo)準(zhǔn):GB 1483.1-2008;IEC 60061-3:2004適用于E14螺口燈頭的電光源燈泡的質(zhì)量檢測。
通規(guī)Go (IEC 7006-27F-1),
The shape part of the edge of the thread shall be broken with radius of 0.2mm to 0.3mm.
量規(guī)螺紋邊口應(yīng)以0.2~0.3mm半徑倒圓。
Purpose目的:
To check the maximum dimensions of the screw thread and dimension T1 minimum of caps on finished lamps.
檢查成品燈E14燈頭螺紋zui大尺寸和T1的zui小值
Testing測試方法:
Whenthe cap on a finished lamp has been screwed into the gauge as far as it will go, the center contact shall be co-planar with, or project beyond, surface X.
當(dāng)成品燈上的燈頭完全旋入量規(guī)內(nèi)時,燈頭中心觸點應(yīng)與X面共面或凸出X面。
止規(guī)Not go (IEC 7006-28B-1),
Purpose目的:
To check the minimum outside (major) diameter of the screw thread.
檢查成品燈燈頭螺紋zui小外徑.
Testing測試方法:
Whenthe gauge is placed over the thread of the cap on a finished lamp, held cap uppermost, the center contact shall not project beyond surface“X”. Only the weight of the gauge itself shall be used in the test.
當(dāng)量規(guī)套在成品燈的燈頭螺紋上時,燈頭中心觸點不應(yīng)凸出量規(guī)的X面,見嚴(yán)禁利用量規(guī)的自身重量進行。
S1規(guī)Go for S1 dimension gauge (IEC 7006-27G-1),
Purpose目的:
To check the dimensions S1 minimum and S1 maximum of E14 caps on finished lamps.
檢驗成品燈上E14燈頭尺寸S1的zui大值和zui小值。
Testing測試方法:
When the cap on a finished lamp has been pushed into the gauge as far as it will go, the plunger surface“W” shall be co-planar with or project beyond surface“X” but it shall not project beyond surface“Y”.
當(dāng)成品燈的燈頭完全插入量規(guī)時,塞柱的W面應(yīng)與X面共面或凸出X面,但不得凸出Y面。
接觸規(guī)Contact-making (IEC 7006-54-2),
Purpose目的:
To check lamp dimensions for contact making in IEC holders.
檢驗燈在燈座中有關(guān)接觸性能的尺寸。
Testing測試方法:
The shape of the lamp with regard to the fit in the lampholder is assured to be correct. If the lamp can be pushed into the gauge till plane W reaches plane V or project beyond it. The application of this gauge is restricted to the following lamps when they are fitted with E14 caps, in accordance with sheet 7004-23: candle lamps/round bulb lamps/domestic tubular lamps/pygmy lamps.
如果燈插入量規(guī)時,W面可與應(yīng)V面共面或凸出V面,則可認(rèn)為燈的形狀與燈座的配合是合格的。此量規(guī)僅適用檢驗裝有符合IEC7004-23中所示的E14燈頭的燭形燈,球形燈,家用管形燈和小型燈。
防意外接觸規(guī)(防觸電)Protection against accidental contact during insertion (IEC 7006-55-2)
Purpose目的:
To check protection againstaccidental contact during insertion of caps E14 on finished lamps.
檢驗成品燈上E14燈頭在插入時防止意外接觸性能。
Testing測試方法:
The shape of the lamp with regard to protection againstaccidental contact is assumed to be correct if, when the lamp is pushed as far as possible into the gauge, surface W does not protrude beyond surface V. The application of this gauge is restricted to the following lamps when they are fitted with E14 caps, in accordance with sheet 7004-23: candle lamps/round bulb lamps/domestic tubular lamps/pygmy lamps.
如果燈頭完全插入量規(guī)時,W面沒有凸出V面,則可認(rèn)為燈的防意外接觸性能是合格的。此量規(guī)僅適用檢驗裝有符合IEC7004-23中所示的E14燈頭的燭形燈,球形燈,家用管形燈和小型燈。